Chimney Framing Checklist

by Build Your Own Home · 1 comment

in Construction Inspection,Framing

  • Sections must be balloon framed. Use of random length material is preferred to ensure story-height segments are interconnected. Framing straps (48″ length minimum) are a suitable substitute.
  • If the chimney penetrates the roof, the opening must be framed on all sides by either header or trimmer blocking, as required (2×6 material minimum). Headers may be a single member as long as the length does note exceed 4 feet.
chimney framing details

chimney framing details

  • The nearest portion of any chimney framing above the rafters must be offset at least 8″ from any valley
  • Chimney height must extend 2 feet above the nearest portion of roof within 10 feet, but not less than 3 feet above the point where the chimney passes through the roof
  • Minimum chimney cricket height in accordance with included diagrams. Brick clad chimneys require a cricket 12″ wider than chimney framing (6″ at each side) to accommodate brick veneer.

cricket dimensions

chimney height criteria